VCA GROUPS//.
Using top quality SSM2018 devices the 8 VCA groups enable
powerful control of input channel fader levels without compromising
audio performance. The Allen & Heath design team have added
extended VCA facilities, giving you more for your investment.
PAFL - Each VCA group can be checked using its PAFL switch.
This has the same effect as pressing all the PAFL buttons on
channels assigned to that group. PFL routes assigned channel
pre-fader signals to the monitor, ideal for checking signal
presence before raising the group fader. In AFL mode the channel
post-fader post-image signals are routed in stereo so that the
contribution of the group to the mix can be heard ‘in-place’.
Mute - Mutes all the channels assigned to the VCA group. This
also affects the channel pre-fade, post-mute sends. The VCA
mutes effectively provide a further 8 mute groups.
Scenes - Channel VCA assignments can be stored in the
snapshot memories. For example, in a complex automated theatre
production, a group assigned as ‘lead vocal’ can have different
channels assigned as lead according to scene.
A&H//ML5000
VCA GROUPS EXPLAINED//.
VCA’s (Voltage Controlled Amplifiers) provide an important
alternative to audio su/jointfilesconvert/363013/bgroups for simultaneously controlling the
level of more than one channel using a single fader.
Unlike an audio su/jointfilesconvert/363013/bgroup, a VCA group simply controls the fader
levels of assigned channels using a remote voltage from the group
fader. Audio is not routed through the group. This means that all
post-fade outputs from assigned channels will be affected by the
VCA master faders.
This has important benefits: The balance between the effects and
direct signals is maintained, for example the reverb level returned
elsewhere in the console also follows the group fader movements.
A single VCA group fader is all that is required to control a stereo or
LCR group. This would take 2 or 3 faders using audio groups if the
channel pan image is to be maintained. The relative balance
between all outputs is maintained when moving VCA group faders.
A channel can be assigned to more than one VCA group. This lets
you assign multi-level groups, or even a ‘grand master’, impossible
with audio groups.
Conventional audio groups are still useful when you need to insert a
signal processor to affect a group of signals. Fewer such groups are
required on a VCA equipped console. For this reason the ML5000
provides mode switching to reconfigure unused audio groups as
fully featured aux sends.